Maximize DOOH revenue with Chipshow’s energy-efficient outdoor LED video walls. Featuring 71.5mm ultra-slim designs, CE compliance, and EU local stock.
Elevate US indoor commercial spaces with Chipshow LED. UL-certified, ADA-compliant, fine-pitch video walls and transparent screens. Dispatched from California stock.
Elevate US indoor commercial spaces with Chipshow LED. UL-certified, ADA-compliant, fine-pitch video walls and transparent screens. Dispatched from California stock.
Elevate your worship experience with broadcast-ready Church LED Video Walls. ETL certified, front-serviceable for volunteers, and in stock in California.
For Sign Builders · Sign Companies · Integrators
Outdoor LED Display Modules for the Cabinet You Build
Start with your cabinet dimensions, message type and viewing conditions. Compare 320×320 mm P6.67, P10 and P16 module configurations, then send your project inputs for an engineering review.
Chipshow supplies the LED modules and specification support. Your sign company keeps the cabinet fabrication, installation and local customer relationship.
Module photo sequence · front, rear and cabinet-fit views
320×320 mm Module size, from the supplied parameter table
P6.67 / P10 / P16 Available listed pitches
5,500–8,500 Listed brightness, cd/m²
1,920 / 3,840 Hz Listed refresh options
ICE / SMD / DIP LED configurations in table
How we work with sign companies
Module Supplier and Sign Builder
Chipshow focuses on module selection and technical matching while your team handles the cabinet, installation and local customer relationship.
Chipshow supplies and supports
Outdoor LED module shortlist based on project inputs
Model-level specification review
Module-grid and cabinet-format discussion
Wiring/control recommendations for review
Order-specific documentation and spare-parts planning
The sign company owns
Cabinet and support-structure fabrication
Final electrical and thermal design
Field installation, access and weather sealing
Permitting, listing and local code compliance
End-customer relationship and service contract
01
Send cabinet inputs
Opening, overall size, access direction, power, controller and quantity.
02
Match the module
Compare pitch, LED type, resolution, scan, refresh and listed brightness.
03
Review the layout
Confirm grid count, total resolution, signal path and service clearances.
04
Approve order specs
Confirm the final configuration in the approved quotation and drawing.
North American sign formats
Selection Starts With the Sign
These sign types describe common purchasing contexts. Final pitch and module selection depend on sign dimensions, content, distance, sunlight, access and local requirements.
Roadside entrance
Digital Monument Sign
Low-profile sign structures for schools, churches, retail entrances and commercial properties.
On-premise messaging
EMC / Message Center
Text, logo and promotional content where message legibility and service access drive selection.
Longer viewing distance
Pylon & Pole Sign
Elevated sign structures where pixel pitch, brightness and safe maintenance are reviewed together.
Restricted rear access
Wall-Mounted Sign
Facade and shallow-cabinet applications where the service method should be confirmed early.
Product views
Inspect the Hardware
These photographs show the display face and rear construction. Exact housing, connector and service details remain model-specific and are confirmed in the approved drawing.
Display face and rear housingUse both sides when reviewing cabinet depth, access direction and visual output.Front and rear constructionConfirm the exact rear layout and connector position against the selected model.LED face and enclosureCompare LED type, pitch, scan, brightness and physical format as one configuration.Display and mechanical layoutUse the approved specification and drawing as the basis for final cabinet design.
Module comparison
Compare verified module configurations.
Review pitch, LED type, resolution, drive mode, refresh rate and listed brightness. Final model selection and cabinet fit are confirmed against your project inputs and approved drawing.
Series / configuration
Pitch
LED type
Module
Resolution
Drive
Refresh
Brightness
Cabinet code
C-Fit-Easy 6.67 ICE
P6.67
ICE LEDs
320×320 mm
48×48
1/6
1,920 Hz
5,500 cd/m²
MA960
C-Fit-Easy 10 ICE
P10
ICE LEDs
320×320 mm
32×32
1/2
1,920 Hz
5,500 cd/m²
MA960
C-Fit-Easy 6.67U06
P6.67
SMD2727
320×320 mm
48×48
1/6
1,920 Hz
8,000 cd/m²
MA640 / MA960
C-Fit-Easy 10U02
P10
SMD3535
320×320 mm
32×32
1/2
3,840 Hz
6,000 cd/m²
MA640 / MA960
C-Fit-Easy 10U04
P10
DIP347
320×320 mm
32×32
1/4
1,920 Hz
8,500 cd/m²
MA640 / MA960
C-Fit-Easy 16U01
P16
DIP347
320×320 mm
20×20
Static
1,920 Hz
8,500 cd/m²
MA640 / MA960
C-Easy 6.67U06
P6.67
SMD2727
320×320 mm
48×48
1/6
1,920 Hz
8,000 cd/m²
MA1280
C-Easy 10U02
P10
SMD3535
320×320 mm
32×32
1/2
3,840 Hz
6,000 cd/m²
MA1280
C-Easy 10U04
P10
DIP347
320×320 mm
32×32
1/4
1,920 Hz
8,500 cd/m²
MA1280
C-Easy 16U01
P16
DIP347
320×320 mm
20×20
Static
1,920 Hz
8,500 cd/m²
MA1280
Brightness values are listed parameter-table values, not a guarantee for every operating condition. Confirm exact full model code, cabinet code, connector layout, service method, IP rating, certification, warranty and approved order specification before publication or purchase.
Prepare your request
Send Your Project Inputs
These eight inputs help us review pitch, module grid and service access before we prepare the project recommendation.
Send these 8 project inputs
Cabinet inside opening and overall dimensions
Single- or double-face sign
Target module grid or total display size
Closest and typical viewing distance
Primary content: text, logos, images or video
Front and rear service clearance
Power, controller and connection preference
Quantity, spare-module plan and required date
What the review delivers
Model shortlist Pitch, LED type, scan, refresh and brightness compared against the request.
Grid review Module count, total resolution and cabinet-code discussion for engineering review.
Wiring/control notes Recommended topology and component list, subject to final project approval.
Order documentation Approved specification, drawing and relevant model-level documentation.
Compliance note: the LED module is one component of the completed sign. Final cabinet, power, wiring, weather protection, structural design, listing, permitting and installation remain subject to the completed sign assembly and local authority requirements.
Sign-company FAQ
FAQ Before You Order
Use these answers to prepare the dimensions, viewing conditions and service information needed for the next review.
Do you supply modules for sign companies that build their own cabinets?
Yes. Share the cabinet dimensions, intended module grid, viewing conditions and service access. Chipshow can review the module match while you retain cabinet fabrication, installation and local permitting.
Which outdoor LED module specifications are listed?
The supplied parameter table lists 320×320 mm configurations in P6.67, P10 and P16 with ICE, SMD2727, SMD3535 and DIP347 options. It includes resolution, drive mode, refresh and brightness by configuration.
Which pitch should I use for a monument sign or EMC?
Viewing distance is only one input. Send the display dimensions, content type, closest viewer, road speed and daylight exposure. We will compare the listed P6.67, P10 and P16 configurations based on your actual sign dimensions, content and site conditions.
Is front service available?
Service method must be confirmed by exact model and approved drawing. Tell us whether rear access is available; we will recommend a configuration only after checking that requirement.
Does a module certification cover the completed sign?
Module-level certification is one part of the picture. Certification and inspection requirements can apply to the completed sign, cabinet, power system and installation. Request model-level documentation and confirm the final assembly with the responsible engineer or authority.
What should I send for pricing?
Send cabinet dimensions, display size, pitch preference, quantity, service access, content type, power/controller information and requested delivery date. That produces a more useful quote than quantity alone.
Get the Module Match
Include the eight project inputs above and attach any cabinet drawing or photo you already have.