Chipshow Outdoor LED Display Modules – Chipshow NA

Chipshow NA

For Sign Builders · Sign Companies · Integrators

Outdoor LED Display Modules

Start with your cabinet dimensions, message type and viewing conditions. Compare 320×320 mm P6.67, P10 and P16 module configurations, then send us the project inputs for an engineering match.

Chipshow supplies the LED hardware and matching support. Your sign company keeps the cabinet fabrication, installation and local customer relationship.

320×320 mm
Module size in supplied table

P6.67 / P10 / P16
Available listed pitches

5,500–8,500
Listed brightness, cd/m²

1,920 / 3,840 Hz
Listed refresh options

ICE / SMD / DIP
LED configurations in table

How we work with sign companies

We build the hardware layer. You build the sign.

Chipshow focuses on module selection and technical matching while your team controls the cabinet, installation and local customer relationship.

Chipshow supplies and supports

  • Outdoor LED module shortlist based on project inputs
  • Model-level specification review
  • Module-grid and cabinet-format discussion
  • Wiring/control recommendations for review
  • Order-specific documentation and spare-parts planning

The sign company owns

  • Cabinet and support-structure fabrication
  • Final electrical and thermal design
  • Field installation, access and weather sealing
  • Permitting, listing and local code compliance
  • End-customer relationship and service contract

01

Send cabinet inputs

Opening, overall size, access direction, power, controller and quantity.

02

Match the module

Compare pitch, LED type, resolution, scan, refresh and listed brightness.

03

Review the layout

Confirm grid count, total resolution, signal path and service clearances.

04

Approve order specs

The approved quotation and drawing—not this web page—control the final configuration.

North American sign formats

Start from the sign

These routes describe the purchasing context. Final pitch and module selection depend on sign dimensions, content, distance, sunlight, access and local requirements.

Replace with approved digital monument sign application photo

Roadside entrance

Digital Monument Sign

Low-profile sign structures for schools, churches, retail entrances and commercial properties.

Replace with approved EMC or message center application photo

On-premise messaging

EMC / Message Center

Text, logo and promotional content where message legibility and service access drive selection.

Replace with approved pylon or pole sign application photo

Longer viewing distance

Pylon & Pole Sign

Elevated sign structures where pixel pitch, brightness and safe maintenance need joint review.

Replace with approved wall-mounted sign application photo

Restricted rear access

Wall-Mounted Sign

Facade and shallow-cabinet applications where the approved service method matters early.

Module comparison

Compare verified module configurations.

Review pitch, LED type, resolution, drive mode, refresh rate and listed brightness. Final model selection and cabinet fit are confirmed against your project inputs and approved drawing.

Series / configuration Pitch LED type Module Resolution Drive Refresh Brightness Cabinet code
C-Fit-Easy 6.67 ICE P6.67 ICE LEDs 320×320 mm 48×48 1/6 1,920 Hz 5,500 cd/m² MA960
C-Fit-Easy 10 ICE P10 ICE LEDs 320×320 mm 32×32 1/2 1,920 Hz 5,500 cd/m² MA960
C-Fit-Easy 6.67U06 P6.67 SMD2727 320×320 mm 48×48 1/6 1,920 Hz 8,000 cd/m² MA640 / MA960
C-Fit-Easy 10U02 P10 SMD3535 320×320 mm 32×32 1/2 3,840 Hz 6,000 cd/m² MA640 / MA960
C-Fit-Easy 10U04 P10 DIP347 320×320 mm 32×32 1/4 1,920 Hz 8,500 cd/m² MA640 / MA960
C-Fit-Easy 16U01 P16 DIP347 320×320 mm 20×20 Static 1,920 Hz 8,500 cd/m² MA640 / MA960
C-Easy 6.67U06 P6.67 SMD2727 320×320 mm 48×48 1/6 1,920 Hz 8,000 cd/m² MA1280
C-Easy 10U02 P10 SMD3535 320×320 mm 32×32 1/2 3,840 Hz 6,000 cd/m² MA1280
C-Easy 10U04 P10 DIP347 320×320 mm 32×32 1/4 1,920 Hz 8,500 cd/m² MA1280
C-Easy 16U01 P16 DIP347 320×320 mm 20×20 Static 1,920 Hz 8,500 cd/m² MA1280

Brightness values are listed parameter-table values, not a guarantee for every operating condition. Confirm exact full model code, cabinet code, connector layout, service method, IP rating, certification, warranty and approved order specification before publication or purchase.

Prepare your request

Send the details needed for an accurate module match.

These eight inputs help us review pitch, module grid and service access before preparing the project recommendation.

Send these 8 project inputs

  1. Cabinet inside opening and overall dimensions
  2. Single- or double-face sign
  3. Target module grid or total display size
  4. Closest and typical viewing distance
  5. Primary content: text, logos, images or video
  6. Front and rear service clearance
  7. Power, controller and connection preference
  8. Quantity, spare-module plan and required date

What the review should return

Model shortlist
Pitch, LED type, scan, refresh and brightness compared against the request.

Grid review
Module count, total resolution and cabinet-code discussion for engineering review.

Wiring/control notes
Recommended topology and component list, subject to final project approval.

Order documentation
Approved specification, drawing and relevant model-level evidence package.

Compliance boundary: the LED module is one component of the completed sign. Final cabinet, power, wiring, weather protection, structural design, listing, permitting and installation remain subject to the complete assembly and local authority requirements.

Sign-company FAQ

Questions sign companies ask before ordering.

Use these answers to prepare the dimensions, viewing conditions and service information needed for the next review.

Do you supply modules for sign companies that build their own cabinets?

Yes. Share the cabinet dimensions, intended module grid, viewing conditions and service access. Chipshow can review the module match while your sign company retains cabinet fabrication, installation and local permitting.

Which outdoor LED module specifications are listed?

The supplied parameter table lists 320×320 mm configurations in P6.67, P10 and P16 with ICE, SMD2727, SMD3535 and DIP347 options. It includes resolution, drive mode, refresh and brightness by configuration.

Which pitch should I use for a monument sign or EMC?

Viewing distance is only one input. Send the display dimensions, content type, closest viewer, road speed and daylight exposure. We will compare the listed P6.67, P10 and P16 configurations without treating a generic distance rule as a final design.

Is front service available?

Service method must be confirmed by exact model and approved drawing. Tell us whether rear access is available; we will only recommend a configuration after checking that requirement.

Does a module certification cover the completed sign?

Not automatically. Certification and inspection requirements can apply to the completed sign, cabinet, power system and installation. Request model-level documentation and confirm the final assembly with the responsible engineer or authority.

What should I send for pricing?

Send cabinet dimensions, display size, pitch preference, quantity, service access, content type, power/controller information and requested delivery date. That produces a more useful quote than quantity alone.

Send the cabinet. Get the module match.

Include the eight project inputs above and attach any cabinet drawing or photo you already have.